Infant Incubator ECOR007
BEDFORDMED
Availability: | |
---|---|
Medical High-performance Baby Treatment Equipment Infant Care Incubator ECOR007
As a newborn and premature infant treatment and nursing equipment, the infant incubator is widely used in obstetrics and neonatal departments of hospitals at all levels. The use object of the infant incubator is mainly low-weight infants with a weak body temperature adjustment ability, weak and weak baby, and premature babies. By providing the environment with a suitable temperature and humidity, it promotes growth and development and rehabilitation. Because the use objects are weak babies, the infant incubator must achieve high safety, accurate and reliable performance parameters, and sensitive alarm functions to achieve the purpose of expected use.
Product feature:
Medical Infant Incubator ECOR007 Specifications | |
Electrical requirement | ~ 220V 50Hz or ~ 230V 60Hz |
Power consumption | ≤ 450VA |
Air mode temp. range | 25.0ºC~ 37.0ºC |
Skin mode temp. range | 34.0ºC~ 37.0ºC |
Air over temp. range | < 38.0ºC |
Air mode high temp. range | 37.1ºC~ 39.0ºC |
Skin mode high temp. range | 37.1ºC~ 38.0ºC |
High temp. mode alarm | < 40.0ºC |
Air mode alarm | ±3.0ºC |
Skin mode alarm | ±1.0ºC |
Skin sensor accuracy | ≤ ±0.3ºC |
Air control accuracy | ≤ 0.5ºC |
Mattress temp. uniformity | ≤ 0.8ºC |
Noise | ≤ 55dB(A) |
(1) Principle of Infant Incubator
The infant incubator is a equipment that integrates clinical medicine, mechanical manufacturing, electrical control integrated design, computer -aided automatic control, sensor and other advanced technologies. It uses computer technology to perform servo control to the temperature (box temperature/skin temperature) in the box. The proportion of the proportion of the internal air is heated according to the setting temperature to the actual temperature. Baby creates an excellent environment of air purification, suitable temperature and humidity, and similar to maternal uterus, so as to effectively manage the body temperature of the baby, and centralize the baby's pre -operation before and after surgery.
(2) Function of Infant Incubator
The main components of the infant incubator are composed of hosting (including baby cabin, chassis, control box, infusion rack and tray), sensor box, skin temperature sensor, seat seat (cabinet or lifting cabinet), radiation light box (jaundice treatment device) (optional accessories), and weighing device (optional accessories).
The infant incubator has a temperature control system and a humidity control system. The temperature control system includes two control working modes: air mode and skin temperature mode. Control of temperature heating output under air mode: The air temperature detected by the temperature sensor in the infant incubator is from the thermal output of the control heater; the control of the temperature heating output under the skin temperature mode: The skin temperature detected according to the temperature sensor comes from the heat output of the control heater. Humidity control system: The humidity detected by the humidity sensor in the infant incubator comes from the humidifier in the water tank.
FAQ
Q1: What's your guarantee?
All our products have 1 year guarantee, if any quality problem can contact us.
Q2: What's your delivery time ?
The delivery time is 25-35 working days. The specific delivery time depends on the items and the quantity of your order.
Q3: What's your minimum order quantity?
MOQ is 1 set.
Q4. Do you test all your goods before delivery?
Yes, we have 100% test before delivery.
Medical High-performance Baby Treatment Equipment Infant Care Incubator ECOR007
As a newborn and premature infant treatment and nursing equipment, the infant incubator is widely used in obstetrics and neonatal departments of hospitals at all levels. The use object of the infant incubator is mainly low-weight infants with a weak body temperature adjustment ability, weak and weak baby, and premature babies. By providing the environment with a suitable temperature and humidity, it promotes growth and development and rehabilitation. Because the use objects are weak babies, the infant incubator must achieve high safety, accurate and reliable performance parameters, and sensitive alarm functions to achieve the purpose of expected use.
Product feature:
Medical Infant Incubator ECOR007 Specifications | |
Electrical requirement | ~ 220V 50Hz or ~ 230V 60Hz |
Power consumption | ≤ 450VA |
Air mode temp. range | 25.0ºC~ 37.0ºC |
Skin mode temp. range | 34.0ºC~ 37.0ºC |
Air over temp. range | < 38.0ºC |
Air mode high temp. range | 37.1ºC~ 39.0ºC |
Skin mode high temp. range | 37.1ºC~ 38.0ºC |
High temp. mode alarm | < 40.0ºC |
Air mode alarm | ±3.0ºC |
Skin mode alarm | ±1.0ºC |
Skin sensor accuracy | ≤ ±0.3ºC |
Air control accuracy | ≤ 0.5ºC |
Mattress temp. uniformity | ≤ 0.8ºC |
Noise | ≤ 55dB(A) |
(1) Principle of Infant Incubator
The infant incubator is a equipment that integrates clinical medicine, mechanical manufacturing, electrical control integrated design, computer -aided automatic control, sensor and other advanced technologies. It uses computer technology to perform servo control to the temperature (box temperature/skin temperature) in the box. The proportion of the proportion of the internal air is heated according to the setting temperature to the actual temperature. Baby creates an excellent environment of air purification, suitable temperature and humidity, and similar to maternal uterus, so as to effectively manage the body temperature of the baby, and centralize the baby's pre -operation before and after surgery.
(2) Function of Infant Incubator
The main components of the infant incubator are composed of hosting (including baby cabin, chassis, control box, infusion rack and tray), sensor box, skin temperature sensor, seat seat (cabinet or lifting cabinet), radiation light box (jaundice treatment device) (optional accessories), and weighing device (optional accessories).
The infant incubator has a temperature control system and a humidity control system. The temperature control system includes two control working modes: air mode and skin temperature mode. Control of temperature heating output under air mode: The air temperature detected by the temperature sensor in the infant incubator is from the thermal output of the control heater; the control of the temperature heating output under the skin temperature mode: The skin temperature detected according to the temperature sensor comes from the heat output of the control heater. Humidity control system: The humidity detected by the humidity sensor in the infant incubator comes from the humidifier in the water tank.
FAQ
Q1: What's your guarantee?
All our products have 1 year guarantee, if any quality problem can contact us.
Q2: What's your delivery time ?
The delivery time is 25-35 working days. The specific delivery time depends on the items and the quantity of your order.
Q3: What's your minimum order quantity?
MOQ is 1 set.
Q4. Do you test all your goods before delivery?
Yes, we have 100% test before delivery.