Infant Incubator ECOR001
BEDFORDMED
Availability: | |
---|---|
Hospital Premature Baby Treatment Equipment Infant Care Incubator ECOR001
The use object of the infant incubator is mainly low -weight infants with a weak body temperature adjustment ability, weak and weak baby, and premature babies.
By providing the environment with a suitable temperature and humidity, it promotes growth and development and rehabilitation. Because the use objects are weak babies, the infant incubator must achieve high safety, accurate and reliable performance parameters, and sensitive alarm functions to achieve the purpose of expected use.
The infant incubator has a temperature control system and a humidity control system. The temperature control system includes two control working modes: air mode and skin temperature mode. Control of temperature heating output under air mode: The air temperature detected by the temperature sensor in the infant incubator is from the thermal output of the control heater; the control of the temperature heating output under the skin temperature mode: The skin temperature detected according to the temperature sensor comes from the heat output of the control heater. Humidity control system: The humidity detected by the humidity sensor in the infant incubator comes from the humidifier in the water tank.
The machine and seats are used as auxiliary parts to support the cultivation box and other components, and provide the corresponding work height according to the needs. Radiation light box (jaundice treatment device) has the function of treating bilirubin in the treatment of infants. The weighing system has the function of monitoring the weight change of the baby at any time.
LCD Touch Screen
displays temp/humidity/ concentration
Data is recorded with 72 hours.Big Monitor tray, can be used easyly.
Medical Neonatal Incubator Specifications | |||
Model | ECOR001 | ECOR002 | ECOR003 |
Electrical requirement | ~ 220V 50Hz | ||
Heater power | 550VA | ||
Air mode temp.range | 25.0ºC~ 37.0ºC | ||
Skin mode temp. range | 34.0ºC~ 37.0ºC | ||
Air mode temp. alarm | < 38.0ºC | ||
Skin mode temp. alarm | < 40.0ºC (Air temp.) | ||
Air mode high temp. range | 37.1ºC~ 39.0ºC | ||
Skin mode high temp. range | 37.1ºC~ 38.0ºC | ||
High temp. mode alarm | < 40.0ºC Air temp. | ||
Air mode temp. display range | 20.0ºC~ 45.0ºC | ||
Skin mode temp. display range | 25.0ºC~ 45.0ºC | ||
Air mode alarm | ±3.0ºC | ||
Skin mode alarm | ±1.0ºC | ||
Skin temp. sensor accuracy | ±0.3ºC | ||
Temp. control accuracy | ≤ 0.5ºC | ||
Mattress temp. uniformity | ≤ 0.8ºC | ||
Humidity control range | 30-90%RH | ||
Humidity display range | 0-99.9%RH | ||
O2 cocentration range | - | 20-60%O2 | |
O2 cocentration alarm | - | ±5%O2 | |
O2 cocentration display range | - | 0-99.9% | |
O2 cocentration display accuracy | - | ±2%O2 | |
Electrical scale weight range | - | 0.1-8Kg | |
Electrical scale display accuracy | - | ±50g |
FAQ
Q1: What's your guarantee?
All our products have 1 year guarantee, if any quality problem can contact us.
Q2: What's your delivery time ?
The delivery time is 25-35 working days. The specific delivery time depends on the items and the quantity of your order.
Q3: What's your minimum order quantity?
MOQ is 1 set.
Q4. Do you test all your goods before delivery?
Yes, we have 100% test before delivery.
Hospital Premature Baby Treatment Equipment Infant Care Incubator ECOR001
The use object of the infant incubator is mainly low -weight infants with a weak body temperature adjustment ability, weak and weak baby, and premature babies.
By providing the environment with a suitable temperature and humidity, it promotes growth and development and rehabilitation. Because the use objects are weak babies, the infant incubator must achieve high safety, accurate and reliable performance parameters, and sensitive alarm functions to achieve the purpose of expected use.
The infant incubator has a temperature control system and a humidity control system. The temperature control system includes two control working modes: air mode and skin temperature mode. Control of temperature heating output under air mode: The air temperature detected by the temperature sensor in the infant incubator is from the thermal output of the control heater; the control of the temperature heating output under the skin temperature mode: The skin temperature detected according to the temperature sensor comes from the heat output of the control heater. Humidity control system: The humidity detected by the humidity sensor in the infant incubator comes from the humidifier in the water tank.
The machine and seats are used as auxiliary parts to support the cultivation box and other components, and provide the corresponding work height according to the needs. Radiation light box (jaundice treatment device) has the function of treating bilirubin in the treatment of infants. The weighing system has the function of monitoring the weight change of the baby at any time.
LCD Touch Screen
displays temp/humidity/ concentration
Data is recorded with 72 hours.Big Monitor tray, can be used easyly.
Medical Neonatal Incubator Specifications | |||
Model | ECOR001 | ECOR002 | ECOR003 |
Electrical requirement | ~ 220V 50Hz | ||
Heater power | 550VA | ||
Air mode temp.range | 25.0ºC~ 37.0ºC | ||
Skin mode temp. range | 34.0ºC~ 37.0ºC | ||
Air mode temp. alarm | < 38.0ºC | ||
Skin mode temp. alarm | < 40.0ºC (Air temp.) | ||
Air mode high temp. range | 37.1ºC~ 39.0ºC | ||
Skin mode high temp. range | 37.1ºC~ 38.0ºC | ||
High temp. mode alarm | < 40.0ºC Air temp. | ||
Air mode temp. display range | 20.0ºC~ 45.0ºC | ||
Skin mode temp. display range | 25.0ºC~ 45.0ºC | ||
Air mode alarm | ±3.0ºC | ||
Skin mode alarm | ±1.0ºC | ||
Skin temp. sensor accuracy | ±0.3ºC | ||
Temp. control accuracy | ≤ 0.5ºC | ||
Mattress temp. uniformity | ≤ 0.8ºC | ||
Humidity control range | 30-90%RH | ||
Humidity display range | 0-99.9%RH | ||
O2 cocentration range | - | 20-60%O2 | |
O2 cocentration alarm | - | ±5%O2 | |
O2 cocentration display range | - | 0-99.9% | |
O2 cocentration display accuracy | - | ±2%O2 | |
Electrical scale weight range | - | 0.1-8Kg | |
Electrical scale display accuracy | - | ±50g |
FAQ
Q1: What's your guarantee?
All our products have 1 year guarantee, if any quality problem can contact us.
Q2: What's your delivery time ?
The delivery time is 25-35 working days. The specific delivery time depends on the items and the quantity of your order.
Q3: What's your minimum order quantity?
MOQ is 1 set.
Q4. Do you test all your goods before delivery?
Yes, we have 100% test before delivery.